<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Central Inverter &#8211; Trang của tôi</title>
	<atom:link href="https://ptechco.com/product-category/bo-hoa-luoi-inverter/inverter-kstar/central-inverter/feed/" rel="self" type="application/rss+xml" />
	<link>https://ptechco.com</link>
	<description></description>
	<lastBuildDate>Mon, 18 Nov 2024 12:36:55 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://ptechco.com/wp-content/uploads/2019/04/Logo100x100.png</url>
	<title>Central Inverter &#8211; Trang của tôi</title>
	<link>https://ptechco.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GSM1250/GSM1500</title>
		<link>https://ptechco.com/product/gsm1250-gsm1500/</link>
					<comments>https://ptechco.com/product/gsm1250-gsm1500/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 12:30:31 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=2002</guid>

					<description><![CDATA[<h2>General Features</h2>
<a href="https://ptechco.com/gsm1250-gsm1500-2/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="pdf-icon" width="16" height="16" />GSM1250 GSM1500.pdf</a>
<ul>
 	<li>Max. PV voltage up to 1500V</li>
 	<li>Max. 12 DC inputs</li>
 	<li>Dustproof protection</li>
 	<li>Modular design for Easy maintenance</li>
 	<li>Max. DC/AC ratio up to 1.5</li>
 	<li>Full power output under 55℃</li>
 	<li>AGC/AVC,LVRT/HVRT/FRT function</li>
 	<li>SVG function at night</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #ff9800;">GSM1250/GSM1500</span></h2>
<p><a href="https://ptechco.com/gsm1250-gsm1500-2/" target="_blank" rel="noopener noreferrer"><img decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="pdf-icon" width="16" height="16" />GSM1250 GSM1500.pdf</a></p>
<p>GSM1250/GSM1500 PV inverter is a three-phase central inverter whose Max. DC intput voltage is 1500Vdc. It is applicable for large-scale centralized PV power plants and can greatly reduce the total investment. It is lower loss, higher efficiency and higher reliability.</p>
<p><iframe src="https://www.youtube.com/embed/2vXJDrRmpg8" width="400" height="190" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></p>
<h2><span style="color: #ff9800;">Technical Parameters</span></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Model</span></strong></td>
<td style="text-align: center;"><strong><span style="color: #ff9800;">GSM1250</span></strong></td>
<td style="text-align: center;"><strong><span style="color: #ff9800;">GSM1500</span></strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Input(DC)</span></strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td></td>
<td></td>
<td></td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="2">1500Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;">800~1300Vdc</td>
<td style="text-align: center;">900~1300Vdc</td>
</tr>
<tr>
<td>Max. DC input number</td>
<td style="text-align: center;">10</td>
<td style="text-align: center;">12</td>
</tr>
<tr>
<td>Max. input current</td>
<td style="text-align: center;" colspan="2">1750A                                                      1870A</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Output(AC)</span></strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Rated output power</td>
<td style="text-align: center;">1250KW</td>
<td style="text-align: center;">1500KW</td>
</tr>
<tr>
<td>Rated output voltage</td>
<td style="text-align: center;">550Vac</td>
<td style="text-align: center;">600Vac</td>
</tr>
<tr>
<td>Output voltage range</td>
<td style="text-align: center;" colspan="2">(1±10%)×Rated AC Voltage  (adjustable ±5%,±10%,±15%)</td>
</tr>
<tr>
<td>Grid frequency range</td>
<td style="text-align: center;" colspan="2">50 / 60Hz（±4.5Hz）（adjustable）</td>
</tr>
<tr>
<td>Rated AC output current</td>
<td style="text-align: center;">1312A</td>
<td style="text-align: center;">1443A</td>
</tr>
<tr>
<td>Max. AC  output current</td>
<td style="text-align: center;">1443A</td>
<td style="text-align: center;">1443A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="2">1  ( 0.9 leading – 0.9 lagging) (adjustable)</td>
</tr>
<tr>
<td style="text-align: left;">THDI</td>
<td style="text-align: center;" colspan="2">＜3%</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Efficiency</span></strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;" colspan="2">99.0%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="2">98.7%</td>
</tr>
<tr>
<td>MPPT efficiency</td>
<td style="text-align: center;" colspan="2">＞99%</td>
</tr>
<tr>
<td>Standby（night time）losses</td>
<td style="text-align: center;" colspan="2">＜50W</td>
</tr>
<tr>
<td>Cooling type</td>
<td style="text-align: center;" colspan="2">Forced air cooling</td>
</tr>
<tr>
<td>Communication interface</td>
<td style="text-align: center;" colspan="2">RS485, external Ethernet (optional)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/gsm1250-gsm1500/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GSL Series 1000-1250KW</title>
		<link>https://ptechco.com/product/gsl-series-1000-1250kw/</link>
					<comments>https://ptechco.com/product/gsl-series-1000-1250kw/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 12:04:12 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1994</guid>

					<description><![CDATA[<h2>General Features</h2>
<a href="https://ptechco.com/gsl-series-pv-inverter-2/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="pdf-icon" width="16" height="16" />GSL1000 GSL1250.pdf</a>
<ul>
 	<li>Max. PV voltage up to 1000V</li>
 	<li>High efficiency up to 99%</li>
 	<li>Redundancy control circuits</li>
 	<li>High performance redundancy cooling system</li>
 	<li>Advanced DSP control</li>
 	<li>Zero Voltage Ride Through function</li>
 	<li>Reactive power controller</li>
 	<li>SVG function at night</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #ff9800;">GSL Series 1000-1250KW</span></h2>
<p><a href="https://ptechco.com/gsl-series-pv-inverter-2/" target="_blank" rel="noopener noreferrer"><img decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="pdf-icon" width="16" height="16" />GSL1000 GSL1250.pdf</a></p>
<p>GSL1000 &#8211; GSL1250 series PV inverter is a three-phase central inverter whose rated output voltage is 400Vac. It is applicable for large-scale centralized PV power plant. It has the characteristics of high efficiency and high reliability.</p>
<p><iframe loading="lazy" src="https://www.youtube.com/embed/2vXJDrRmpg8" width="400" height="190" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></p>
<h2><span style="color: #ff9800;">Technical Parameters</span></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>GSL1000</strong></td>
<td style="text-align: center;"><strong>GSL1250</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong>Input(DC)</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Max. DC power</td>
<td style="text-align: center;">1300KW</td>
<td style="text-align: center;">1562KW</td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="2">1000Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="2">580~850Vdc</td>
</tr>
<tr>
<td>Max. DC input number</td>
<td style="text-align: center;" colspan="2">8(320A) / 16(160A)</td>
</tr>
<tr>
<td>Max. input current</td>
<td style="text-align: center;">1935A</td>
<td style="text-align: center;">2420A</td>
</tr>
<tr>
<td style="text-align: center;">Output(AC)</td>
<td colspan="2"></td>
</tr>
<tr>
<td>Raled output power</td>
<td style="text-align: center;">1000KW</td>
<td style="text-align: center;">1250KW</td>
</tr>
<tr>
<td>Raled output voltage</td>
<td style="text-align: center;" colspan="2">400Vac</td>
</tr>
<tr>
<td>Output voltage range</td>
<td style="text-align: center;" colspan="2">(1±15%)*Normal AC Voltage (adjustable ±5%，±10%，±15%，±20%)</td>
</tr>
<tr>
<td>Grid frequency range</td>
<td style="text-align: center;" colspan="2">50 / 60Hz（±4.5Hz），（adjustable）</td>
</tr>
<tr>
<td>Rated AC output current</td>
<td style="text-align: center;">1444A</td>
<td style="text-align: center;">1804A</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">1588A</td>
<td style="text-align: center;">1984A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="2">1（Lagging0.9~Leading0.9）（adjustable）</td>
</tr>
<tr>
<td>THDI</td>
<td style="text-align: center;" colspan="2">＜3%</td>
</tr>
<tr>
<td style="text-align: center;"><strong>Efficiency</strong></td>
<td colspan="2"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;" colspan="2">99.0%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="2">98.7%</td>
</tr>
<tr>
<td>MPPT efficiency</td>
<td style="text-align: center;" colspan="2">＞99%</td>
</tr>
<tr>
<td>Standby（night time）losses</td>
<td style="text-align: center;" colspan="2">＜50W</td>
</tr>
<tr>
<td>Cooling</td>
<td style="text-align: center;" colspan="2">Forced air cooling</td>
</tr>
<tr>
<td>Communication interface</td>
<td style="text-align: center;" colspan="2">RS485, external Ethernet (optional)</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/gsl-series-1000-1250kw/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>GSL Series With Transformer 100-500KW</title>
		<link>https://ptechco.com/product/gsl-series-with-transformer-100-500kw/</link>
					<comments>https://ptechco.com/product/gsl-series-with-transformer-100-500kw/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 11:50:34 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1993</guid>

					<description><![CDATA[<h2>General Features</h2>
<ul>
 	<li>Max. PV voltage up to 1000V</li>
 	<li>High efficiency up to 98.1%</li>
 	<li>Redundancy control circuits</li>
 	<li>High Performance cooling system</li>
 	<li>Advanced DSP control</li>
 	<li>Zero Voltage Ride Through function</li>
 	<li>Reactive power controller</li>
 	<li>SVG function at night</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #ff9800;">GSL Series With Transformer 100-500KW</span></h2>
<p>GSL0100T ~ GSL0500T series PV inverter is a three-phase central inverter integrated with isolated transformer whose rated output voltage is 400Vac. It is applicable for large-scale distributed commercial PV system such as large-scale factory with complex load. It has the characteristics of high reliability and high compatibility.</p>
<h2><iframe loading="lazy" src="https://www.youtube.com/embed/2vXJDrRmpg8" width="400" height="190" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></h2>
<h2><span style="color: #ff9800;">Technical Parameters</span></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>GSL0100T</strong></td>
<td style="text-align: center;"><strong>GSL0250T</strong></td>
<td style="text-align: center;"><strong>GSL0500T</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Input(DC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. DC power</td>
<td style="text-align: center;">110KW</td>
<td style="text-align: center;">275KW</td>
<td style="text-align: center;">550KW</td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="3">1000Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="3">450~850Vdc</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;" colspan="3">1</td>
</tr>
<tr>
<td>Max. input current</td>
<td style="text-align: center;">240A</td>
<td style="text-align: center;">600A</td>
<td style="text-align: center;">1200A</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Output(AC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Raled output power</td>
<td style="text-align: center;">100KW</td>
<td style="text-align: center;">250KW</td>
<td style="text-align: center;">500KW</td>
</tr>
<tr>
<td>Raled output voltage</td>
<td style="text-align: center;" colspan="3">400Vac</td>
</tr>
<tr>
<td>AC output topology</td>
<td style="text-align: center;" colspan="3">3W+N+PE</td>
</tr>
<tr>
<td>Output voltage range</td>
<td style="text-align: center;" colspan="3">(1±15%)*Normal AC Voltage (adjustable ±5%，±10%，±15%，±20%)</td>
</tr>
<tr>
<td>Grid frequency range</td>
<td style="text-align: center;" colspan="3">50 / 60Hz（±4.5Hz），（adjustable）</td>
</tr>
<tr>
<td>Rated AC output current</td>
<td style="text-align: center;">144A</td>
<td style="text-align: center;">361A</td>
<td style="text-align: center;">722A</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">158A</td>
<td style="text-align: center;">397A</td>
<td style="text-align: center;">794A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="3">1（Lagging0.9~Leading0.9）（adjustable）</td>
</tr>
<tr>
<td>THDI</td>
<td style="text-align: center;" colspan="3">＜3%</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Efficiency</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;">97.7%</td>
<td style="text-align: center;">97.9%</td>
<td style="text-align: center;">98.1%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;">97.4%</td>
<td style="text-align: center;">97.6%</td>
<td style="text-align: center;">97.9%</td>
</tr>
<tr>
<td>MPPT efficiency</td>
<td style="text-align: center;" colspan="3">＞99%</td>
</tr>
<tr>
<td>Standby（night time）losses</td>
<td style="text-align: center;" colspan="3">＜10W</td>
</tr>
<tr>
<td>Cooling</td>
<td style="text-align: center;" colspan="3">Forced air cooling</td>
</tr>
<tr>
<td>Protection rating</td>
<td style="text-align: center;" colspan="3">IP21</td>
</tr>
</tbody>