<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Residential Energy Storage Inverter &#8211; Trang của tôi</title>
	<atom:link href="https://ptechco.com/product-category/bo-hoa-luoi-inverter/inverter-kstar/energy-storage-system/residential-energy-storage-inverter/feed/" rel="self" type="application/rss+xml" />
	<link>https://ptechco.com</link>
	<description></description>
	<lastBuildDate>Mon, 18 Nov 2024 12:36:53 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://ptechco.com/wp-content/uploads/2019/04/Logo100x100.png</url>
	<title>Residential Energy Storage Inverter &#8211; Trang của tôi</title>
	<link>https://ptechco.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KSE 3.6-5K Series (048)</title>
		<link>https://ptechco.com/product/kse-3-6-5k-series-048/</link>
					<comments>https://ptechco.com/product/kse-3-6-5k-series-048/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 11:18:57 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1987</guid>

					<description><![CDATA[<h2>General Features</h2>
<a href="https://ptechco.com/kse-3-2/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSE-3.6K~6K-048 series.pdf</a>
<ul>
 	<li>Solution for energy independence</li>
 	<li>Wall mounted and rack installation (optional)</li>
 	<li>IP65 protection, highly integrated design,light weight,easy for installation on the site</li>
 	<li>Operating in either on-grid mode or off-grid mode</li>
 	<li>Compatible with both lead-acid battery and Li-ion battery</li>
 	<li>Optimal scheme of battery charging and discharging</li>
 	<li>Ultra wide MPPT range: 120Vdc - 500Vdc</li>
 	<li>Fast and easy commissioning via front panel LCD or App</li>
 	<li>Integrated advanced energy managemenl system, battery usage strategies</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2>KSE 3.6-5K Series (048)</h2>
<p><a href="https://ptechco.com/kse-3-2/" target="_blank" rel="noopener noreferrer"><img decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSE-3.6K~6K-048 series.pdf</a></p>
<p>KSE 3.6~5K Series bidirectional energy storage hybrid inverter can control the flow of energy intelligently and protect against power outage. The PV energy can be provided to the load, fed into the public grid and charge the battery during the daytime. And the energy stored in the battery can be discharged to power the load during night time. The public grid can also charge the battery via the hybrid inverter.</p>
<h2>Technical Parameters</h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>KSE-3.6K-048</strong></td>
<td style="text-align: center;"><strong>KSE-4.6K-048</strong></td>
<td style="text-align: center;"><strong>KSE-5K-048</strong></td>
</tr>
<tr>
<td><strong>PV Input Data</strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>PV Max. power</td>
<td style="text-align: center;">4400W</td>
<td style="text-align: center;">6000W</td>
<td style="text-align: center;">6000W</td>
</tr>
<tr>
<td>Max. DC input voltage</td>
<td style="text-align: center;" colspan="3">550Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="3">120~500Vdc</td>
</tr>
<tr>
<td>Nominal input voltage</td>
<td style="text-align: center;" colspan="3"> 420V</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;" colspan="3">2</td>
</tr>
<tr>
<td>MPPT voltage range(for full-load)</td>
<td style="text-align: center;" colspan="3">    184 ~ 500 V                           230 ~ 500 V                           230 ~ 500 V</td>
</tr>
<tr>
<td>Max. PV  input current</td>
<td style="text-align: center;" colspan="3">13A x 2</td>
</tr>
<tr>
<td>AC Output Data(On-grid)</td>
<td colspan="3"></td>
</tr>
<tr>
<td>Nominal AC output power</td>
<td style="text-align: center;">3680W</td>
<td style="text-align: center;">4600W</td>
<td style="text-align: center;">5000W</td>
</tr>
<tr>
<td>Max. AC output power</td>
<td style="text-align: center;">3680W</td>
<td style="text-align: center;">4600W</td>
<td style="text-align: center;">5000W</td>
</tr>
<tr>
<td>Nominal AC voltage</td>
<td style="text-align: center;" colspan="3">230Vac</td>
</tr>
<tr>
<td>AC   voltage range</td>
<td style="text-align: center;" colspan="3">180V~280V</td>
</tr>
<tr>
<td>AC output topology</td>
<td style="text-align: center;" colspan="3">LN+PE, Transformerless (for solar)</td>
</tr>
<tr>
<td>Gril frequency range</td>
<td style="text-align: center;" colspan="3">50 / 60Hz(±5Hz),Adjustable</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">16A</td>
<td style="text-align: center;">20A</td>
<td style="text-align: center;">  22A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="3">(cosΦ) 0.8 Leading ～0.8 Lagging</td>
</tr>
<tr>
<td>THDI</td>
<td colspan="3">
<div style="text-align: center;">&lt;3 % (of nominal power)</div>
</td>
</tr>
<tr>
<td><strong>Battery</strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Battery type</td>
<td style="text-align: center;" colspan="3">Lead-acid or Li-ion battery</td>
</tr>
<tr>
<td>Battery voltage range</td>
<td style="text-align: center;" colspan="3">40~58V</td>
</tr>
<tr>
<td> Battery AH</td>
<td style="text-align: center;" colspan="3">100~2000Ah</td>
</tr>
<tr>
<td> Depth Of Discharge</td>
<td style="text-align: center;" colspan="3">Li-ion 90%DOD(10%~90% adjustable) / Lead-acid 50%DOD(10%~50% adjustable)</td>
</tr>
<tr>
<td>Max. discharging current</td>
<td style="text-align: center;">100A</td>
<td style="text-align: center;" colspan="2">100A</td>
</tr>
<tr>
<td>Max. charging current</td>
<td style="text-align: center;" colspan="3">80A(0~80A)</td>
</tr>
<tr>
<td><strong>Efficiency</strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;" colspan="3">＞97.6%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="3">＞97%</td>
</tr>
<tr>
<td>MPPT efficiency</td>
<td style="text-align: center;" colspan="3">99.5%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/kse-3-6-5k-series-048/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>KSE Series Hybrid Inverter(048S)</title>
		<link>https://ptechco.com/product/kse-series-hybrid-inverter048s/</link>
					<comments>https://ptechco.com/product/kse-series-hybrid-inverter048s/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 10:56:08 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1980</guid>

					<description><![CDATA[<h2>General Features</h2>
<a href="https://ptechco.com/kse-series-hybrid-inverter048s-2/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSE-2K-5K-048S.pdf</a>
<ul>
 	<li>Easy I&#38;M</li>
 	<li>Friendly and Intelligent</li>
 	<li>Safe and Reliable</li>
 	<li>Efficient Conversion</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2>KSE Series Hybrid Inverter(048S)</h2>
<p>KSE Series Hybrid Inverter(048S)</p>
<p><a href="https://ptechco.com/kse-series-hybrid-inverter048s-2/" target="_blank" rel="noopener noreferrer"><img decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSE-2K-5K-048S.pdf</a></p>
<p>KSE Series Hybrid Inverter can control the flow of energy intelligently and protect against power outage. The PV energy can be provided to the load, fed into the public grid and charge the battery during the daytime. And the energy stored in the battery can be discharged to power the load during night time. The public grid can also charge the battery via the hybrid inverter.</p>
<h2>Technical Parameters</h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong> KSE-2K-048S</strong></td>
<td style="text-align: center;"><strong> KSE-3K-048S</strong></td>
<td style="text-align: center;"><strong>KSE-3.6K-048S</strong></td>
<td style="text-align: center;"><strong>KSE-5K-048S</strong></td>
</tr>
<tr>
<td><strong>PV Input Data</strong></td>
<td></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. PV input power</td>
<td style="text-align: center;"> 2600W</td>
<td style="text-align: center;">3900W</td>
<td style="text-align: center;">4800W</td>
<td style="text-align: center;">6000W</td>
</tr>
<tr>
<td>Max. PV input voltage</td>
<td style="text-align: center;" colspan="4">   550Vdc（*1）</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;">  120~500Vdc</td>
<td style="text-align: center;" colspan="3">120~500Vdc</td>
</tr>
<tr>
<td>Rated input voltage</td>
<td style="text-align: center;"> 420Vdc</td>
<td style="text-align: center;" colspan="3">420Vdc</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;"> 1</td>
<td style="text-align: center;" colspan="3">2</td>
</tr>
<tr>
<td>MPPT range for full load</td>
<td style="text-align: center;"> 236~500V</td>
<td style="text-align: center;" colspan="3">       178~500V                    219~500V                         273~500V</td>
</tr>
<tr>
<td>Max. PV input current</td>
<td style="text-align: center;"> 11A</td>
<td style="text-align: center;" colspan="3">11A*2</td>
</tr>
<tr>
<td><strong>AC Output data(On-grid)</strong></td>
<td></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Rated output voltage</td>
<td style="text-align: center;"> 230Vac</td>
<td style="text-align: center;">230Vac</td>
<td style="text-align: center;"> 230Vac</td>
<td style="text-align: center;">230Vac</td>
</tr>
<tr>
<td>
<div>Output voltage range</div>
</td>
<td style="text-align: center;"> 150V~280V</td>
<td style="text-align: center;">150V~280V</td>
<td style="text-align: center;">150V~280V</td>
<td style="text-align: center;">150V~280V</td>
</tr>
<tr>
<td>Output frequency range</td>
<td style="text-align: center;" colspan="4"> 50 / 60Hz (±5Hz)(adjustable)</td>
</tr>
<tr>
<td>Max. current from utility grid</td>
<td style="text-align: center;" colspan="4">  23A</td>
</tr>
<tr>
<td>Max. apparent power from utility grid</td>
<td style="text-align: center;" colspan="4">   5300VA</td>
</tr>
<tr>
<td>Max. power output to utility grid</td>
<td style="text-align: center;">2000W</td>
<td colspan="3">
<div style="text-align: center;"></div>
<div style="text-align: center;">    3000W                                 3680W                       5000W(*2)</div>
</td>
</tr>
<tr>
<td>Max. current output to utility grid</td>
<td style="text-align: center;">9A</td>
<td style="text-align: center;" colspan="3">  13.5A                                   16A                            22A(*3)</td>
</tr>
<tr>
<td>AC output connection</td>
<td style="text-align: center;" colspan="4">L+N+PE, Transformerless</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="4">1(0.8 leading ～0.8 lagging) (adjustable)</td>
</tr>
<tr>
<td>THDi</td>
<td style="text-align: center;" colspan="4"> ＜3%</td>
</tr>
<tr>
<td><strong>Battery Input</strong></td>
<td></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Battery type</td>
<td style="text-align: center;" colspan="4">  Lead-acid or Li-ion</td>
</tr>
<tr>
<td>Rated battery voltage</td>
<td style="text-align: center;" colspan="4">  48V</td>
</tr>
<tr>
<td>Depth of discharging</td>
<td style="text-align: center;" colspan="4">Li-ion 90%DOD(10%~90% adjustable) / Lead-acid 50%DOD(10%~50% adjustable)</td>
</tr>
<tr>
<td><strong>Efficiency</strong></td>
<td></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. conversion efficiency (from battery）</td>
<td style="text-align: center;" colspan="4">  94.0%</td>
</tr>
<tr>
<td>Max. conversion efficiency (from PV）</td>
<td style="text-align: center;" colspan="4">  97.6%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="4">  97.0%</td>
</tr>
<tr>
<td>Protection function</td>
<td style="text-align: center;" colspan="4">  Short Circuit Protection, AC Leakage Fault Protection, Grounding Fault Protection, Anti-islanding Protection, Overload Protection, Surge Protection, DC Polarity Protection</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/kse-series-hybrid-inverter048s/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
