<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Three phase String Grid tied PV Inverter &#8211; Trang của tôi</title>
	<atom:link href="https://ptechco.com/product-category/bo-hoa-luoi-inverter/inverter-kstar/string-inverter/three-phase-string-grid-tied-pv-inverter/feed/" rel="self" type="application/rss+xml" />
	<link>https://ptechco.com</link>
	<description></description>
	<lastBuildDate>Mon, 18 Nov 2024 12:37:07 +0000</lastBuildDate>
	<language>vi</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://ptechco.com/wp-content/uploads/2019/04/Logo100x100.png</url>
	<title>Three phase String Grid tied PV Inverter &#8211; Trang của tôi</title>
	<link>https://ptechco.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>KSG 10-20K Series</title>
		<link>https://ptechco.com/product/ksg-10-20k-series/</link>
					<comments>https://ptechco.com/product/ksg-10-20k-series/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 10:28:58 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1978</guid>

					<description><![CDATA[<h2>General Features</h2>
<img class=" wp-image-1975 alignnone" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/10-20k.png" alt="" width="239" height="61" />

<a href="https://ptechco.com/ksg-10-20k-series/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" /> </a><a href="https://ptechco.com/ksg-10-20k-series/" target="_blank" rel="noopener noreferrer">String Grid-Tied PV Inverter KSG-10K -20K.pdf</a>
<ul>
 	<li>Max. PV voltage up to 1000V</li>
 	<li>2 MPPT</li>
 	<li>High efficiency up to 98.0%</li>
 	<li>IP65 protection</li>
 	<li>Easy installation</li>
 	<li>Reactive power controller</li>
 	<li>Digital controller</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2><span style="color: #ff9800;">KSG 10-20K Series</span></h2>
<p><img decoding="async" class="size-full wp-image-1975 alignnone" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/10-20k.png" alt="" width="255" height="65" /></p>
<p>KSG 10 &#8211; 20K series PV inverter is a three-phase inverter which is applicable for distributed commercial PV system. It is high efficiency, high reliability and easy installation.</p>
<p>KSG 10-20K Series kstar inverter dowload pdf</p>
<p><a href="https://ptechco.com/ksg-10-20k-series/" target="_blank" rel="noopener noreferrer"><img decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />String Grid-Tied PV Inverter KSG-10K -20K.pdf</a></p>
<p><iframe src="https://www.youtube.com/embed/OHWXksKvz1E" width="400" height="190" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></p>
<h2><span style="color: #ff9800;">Technical Parameters</span></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>KSG-10K</strong></td>
<td style="text-align: center;"><strong>KSG-12K</strong></td>
<td style="text-align: center;"><strong>KSG-15K</strong></td>
<td style="text-align: center;"><strong>KSG-17K</strong></td>
<td style="text-align: center;"><strong>KSG-20K</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Input(DC</span>)</strong></td>
<td colspan="5"></td>
</tr>
<tr>
<td>Max. DC power</td>
<td style="text-align: center;">11.5KW</td>
<td style="text-align: center;">13.5KW</td>
<td style="text-align: center;">16.5KW</td>
<td style="text-align: center;">18.5KW</td>
<td style="text-align: center;">22.5KW</td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="5">1000Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="5">250~950Vdc</td>
</tr>
<tr>
<td>Full load MPPT voltage range</td>
<td style="text-align: center;" colspan="5">480~800Vdc</td>
</tr>
<tr>
<td>Min. / Start DC voltage</td>
<td style="text-align: center;" colspan="5">200 / 250Vdc</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;" colspan="5">2</td>
</tr>
<tr>
<td>Strings per MPPT tracker</td>
<td style="text-align: center;" colspan="2">1</td>
<td style="text-align: center;" colspan="3">2</td>
</tr>
<tr>
<td>Max. input current per MPPT tracker</td>
<td style="text-align: center;" colspan="2">13A</td>
<td style="text-align: center;" colspan="3">21A</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Output(AC)</span></strong></td>
<td colspan="5"></td>
</tr>
<tr>
<td>Nominal AC output power</td>
<td style="text-align: center;">10KW</td>
<td style="text-align: center;">12KW</td>
<td style="text-align: center;">15KW</td>
<td style="text-align: center;">17KW</td>
<td style="text-align: center;">20KW</td>
</tr>
<tr>
<td>Max. AC output power</td>
<td style="text-align: center;">11KW</td>
<td style="text-align: center;">13KW</td>
<td style="text-align: center;">16KW</td>
<td style="text-align: center;">18KW</td>
<td style="text-align: center;">22KW</td>
</tr>
<tr>
<td>Nominal AC voltage</td>
<td style="text-align: center;" colspan="5">400Vac</td>
</tr>
<tr>
<td>AC voltage range</td>
<td style="text-align: center;" colspan="5">400Vac±20%</td>
</tr>
<tr>
<td>Nominal AC grid frequency</td>
<td style="text-align: center;" colspan="5">50 / 60Hz</td>
</tr>
<tr>
<td>AC grid frequency range</td>
<td style="text-align: center;" colspan="5">50 / 60Hz（±5Hz）</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">17A</td>
<td style="text-align: center;">20A</td>
<td style="text-align: center;">24A</td>
<td style="text-align: center;">27A</td>
<td style="text-align: center;">32A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="5">Lagging0.8~Leading0.8</td>
</tr>
<tr>
<td>THDI</td>
<td style="text-align: center;" colspan="5">＜3%</td>
</tr>
<tr>
<td>AC connection</td>
<td style="text-align: center;" colspan="5">3W+N+PE / 3W+PE</td>
</tr>
<tr>
<td>Topology</td>
<td style="text-align: center;" colspan="5">Transformerless</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff9800;">Efficiency</span></strong></td>
<td colspan="5"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;" colspan="5">98.0%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="5">97.5%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/ksg-10-20k-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>KSG 30-60K Series</title>
		<link>https://ptechco.com/product/ksg-30-60k-series/</link>
					<comments>https://ptechco.com/product/ksg-30-60k-series/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 10:05:36 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1972</guid>

					<description><![CDATA[<h2><strong>General Features</strong></h2>
<img class="size-full wp-image-1973 alignnone" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/30-60k.png" alt="" width="156" height="61" />

<a href="https://ptechco.com/ksg-36-60k-hv-series-3/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSG-30K KSG-50K KSG-60K.pdf</a>
<ul>
 	<li>Max. PV voltage up to 1000V</li>
 	<li>3 MPPT</li>
 	<li>High efficiency up to 98.6%</li>
 	<li>IP65 protection</li>
 	<li>DC fuse optional</li>
 	<li>String monitoring optional</li>
 	<li>Easy installation</li>
 	<li>Reactive power controller</li>
 	<li>Digital controller</li>
 	<li>DC/AC surge protection</li>
 	<li>Type Ⅱ SPD optional</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2 style="text-align: left;"><span style="color: #ff7e46;">KSG <strong>30-60K</strong>  Series</span></h2>
<p><img loading="lazy" decoding="async" class="size-full wp-image-1973 alignnone" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/30-60k.png" alt="" width="156" height="61" /></p>
<div class="a"><a href="https://ptechco.com/ksg-36-60k-hv-series-3/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSG-30K KSG-50K KSG-60K.pdf</a></div>
<p>KSG 30 ~ 60K series PV inverter is a three-phase inverter whose rated output voltage is 400Vac. It is applicable for distributed commercial PV system. It has the characteristics of high efficiency, high reliability and easy installation.</p>
<p><iframe loading="lazy" src="https://www.youtube.com/embed/wTjJ9sQSTSs?start=6" width="480" height="360" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></p>
<h2><strong><span style="color: #ff7e46;">Technical Parameters</span></strong></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>KSG-30K</strong></td>
<td style="text-align: center;"><strong>KSG-50K</strong></td>
<td style="text-align: center;"><strong>KSG-60K</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Input(DC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. DC power</td>
<td style="text-align: center;">39KW</td>
<td style="text-align: center;">65KW</td>
<td style="text-align: center;">78KW</td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="3">1000Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="3">250~950Vdc</td>
</tr>
<tr>
<td>Full load MPPT voltage range</td>
<td style="text-align: center;">400~800Vdc</td>
<td style="text-align: center;">480~800Vdc</td>
<td style="text-align: center;">500~800Vdc</td>
</tr>
<tr>
<td>Min. / Start DC voltage</td>
<td style="text-align: center;" colspan="3">200 / 250Vdc</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;" colspan="3">3</td>
</tr>
<tr>
<td>Strings per MPPT tracker</td>
<td style="text-align: center;">2</td>
<td style="text-align: center;" colspan="2">4</td>
</tr>
<tr>
<td>Max. input current per MPPT tracker</td>
<td style="text-align: center;">26A</td>
<td style="text-align: center;">36A</td>
<td style="text-align: center;">40A</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Output(AC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Nominal AC output power</td>
<td style="text-align: center;">30KW</td>
<td style="text-align: center;">50KW</td>
<td style="text-align: center;">60KW</td>
</tr>
<tr>
<td>Max. AC output power</td>
<td style="text-align: center;">33KW</td>
<td style="text-align: center;">55KW</td>
<td style="text-align: center;">66KW</td>
</tr>
<tr>
<td>Nominal AC voltage</td>
<td style="text-align: center;" colspan="3">400Vac</td>
</tr>
<tr>
<td>AC voltage range</td>
<td style="text-align: center;" colspan="3">400Vac±20%</td>
</tr>
<tr>
<td>Nominal AC grid frequency</td>
<td style="text-align: center;" colspan="3">50 / 60Hz</td>
</tr>
<tr>
<td>AC grid frequency range</td>
<td style="text-align: center;" colspan="3">50 / 60Hz（±5Hz）</td>
</tr>
<tr>
<td>Nominal AC output current</td>
<td style="text-align: center;">44A</td>
<td style="text-align: center;">72A</td>
<td style="text-align: center;">87A</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">48A</td>
<td style="text-align: center;">80A</td>
<td style="text-align: center;">95A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="3">Lagging0.8~Leading0.8</td>
</tr>
<tr>
<td>THDI</td>
<td style="text-align: center;" colspan="3">＜3%</td>
</tr>
<tr>
<td>AC connection</td>
<td style="text-align: center;" colspan="3">3W+N+PE / 3W+PE</td>
</tr>
<tr>
<td>Topology</td>
<td style="text-align: center;" colspan="3">Transformerless</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Efficiency</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;">98.3%</td>
<td style="text-align: center;" colspan="2">98.6%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;">98.0%</td>
<td style="text-align: center;" colspan="2">98.2%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
					<wfw:commentRss>https://ptechco.com/product/ksg-30-60k-series/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>KSG 36~60K HV Series</title>
		<link>https://ptechco.com/product/ksg-36-60k-hv-series/</link>
					<comments>https://ptechco.com/product/ksg-36-60k-hv-series/#respond</comments>
		
		<dc:creator><![CDATA[Adminss]]></dc:creator>
		<pubDate>Wed, 01 Jan 2020 09:52:17 +0000</pubDate>
				<guid isPermaLink="false">https://ptechco.com/?post_type=product&#038;p=1969</guid>

					<description><![CDATA[<h3>General Features</h3>
<div><a href="https://ptechco.com/ksg-36-60k-hv-series-2/" target="_blank" rel="noopener noreferrer"><img class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSG-36K-60K-HV.pdf</a></div>
<ul>
 	<li>3 MPPT</li>
 	<li>High efficiency up to 98.6%</li>
 	<li>IP65 protection</li>
 	<li>DC fuse optional</li>
 	<li>String monitoring optional</li>
 	<li>Easy installation</li>
 	<li>Reactive power controller</li>
 	<li>Digital controller</li>
 	<li>DC/AC surge protection</li>
 	<li>Type Ⅱ SPD optional</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h2 class="title2 title15"><span style="color: #ff7e46;">KSG 36-60K HV Series</span></h2>
<div class="a">KSG 36 ~ 60K series PV inverter is a three-phase inverter whose rated output voltage is 480Vac. It is applicable for distributed commercial PV system and large-scale centralized PV power plant. It has the characteristics of high efficiency, high reliability and easy installation.</div>
<div><a href="https://ptechco.com/ksg-36-60k-hv-series-2/" target="_blank" rel="noopener noreferrer"><img loading="lazy" decoding="async" class="size-full wp-image-1962 alignleft" src="https://ptechco.com/wp-content/uploads/media/Solar-power/Inverter/Kstar/String-Inverter/pdf.gif" alt="" width="16" height="16" />KSG-36K-60K-HV.pdf</a></div>
<div></div>
<div><iframe loading="lazy" src="https://www.youtube.com/embed/OHWXksKvz1E" width="400" height="190" frameborder="0" allowfullscreen="allowfullscreen"><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span><span data-mce-type="bookmark" style="display: inline-block; width: 0px; overflow: hidden; line-height: 0;" class="mce_SELRES_start">﻿</span></iframe></div>
<h2><span style="color: #ff7e46;">Technical Parameters</span></h2>
<table border="1" cellspacing="0" cellpadding="0" align="left">
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>KSG-36K-HV</strong></td>
<td style="text-align: center;"><strong>KSG-50K-HV</strong></td>
<td style="text-align: center;"><strong>KSG-60K-HV</strong></td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Input(DC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. DC power</td>
<td style="text-align: center;">41KW</td>
<td style="text-align: center;">56KW</td>
<td style="text-align: center;">67KW</td>
</tr>
<tr>
<td>Max. DC voltage</td>
<td style="text-align: center;" colspan="3">1000Vdc</td>
</tr>
<tr>
<td>MPPT voltage range</td>
<td style="text-align: center;" colspan="3">250~950Vdc</td>
</tr>
<tr>
<td>Full load MPPT voltage range</td>
<td style="text-align: center;" colspan="3">550~800Vdc</td>
</tr>
<tr>
<td>Min. / Start DC voltage</td>
<td style="text-align: center;" colspan="3">200 / 250Vdc</td>
</tr>
<tr>
<td>Number of MPPT trackers</td>
<td style="text-align: center;" colspan="3">3</td>
</tr>
<tr>
<td>Strings per MPPT tracker</td>
<td style="text-align: center;">2</td>
<td style="text-align: center;" colspan="2">4</td>
</tr>
<tr>
<td>Max. input current per MPPT tracker</td>
<td style="text-align: center;">26A</td>
<td style="text-align: center;" colspan="2">36A</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Output(AC)</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Nominal AC output power</td>
<td style="text-align: center;">36KW</td>
<td style="text-align: center;">50KW</td>
<td>60KW</td>
</tr>
<tr>
<td>Max. AC output power</td>
<td style="text-align: center;">40KW</td>
<td style="text-align: center;">55KW</td>
<td style="text-align: center;">66KW</td>
</tr>
<tr>
<td>Nominal AC voltage</td>
<td style="text-align: center;" colspan="3">480Vac</td>
</tr>
<tr>
<td>AC voltage range</td>
<td style="text-align: center;" colspan="3">480Vac±10%</td>
</tr>
<tr>
<td>Nominal AC grid frequency</td>
<td style="text-align: center;" colspan="3">50 / 60Hz</td>
</tr>
<tr>
<td>AC grid frequency range</td>
<td style="text-align: center;" colspan="3">50 / 60Hz（±5Hz）</td>
</tr>
<tr>
<td>Nominal AC output current</td>
<td style="text-align: center;">44A</td>
<td style="text-align: center;">61A</td>
<td style="text-align: center;">72A</td>
</tr>
<tr>
<td>Max. output current</td>
<td style="text-align: center;">48A</td>
<td style="text-align: center;">67A</td>
<td style="text-align: center;">80A</td>
</tr>
<tr>
<td>Power factor (cosФ)</td>
<td style="text-align: center;" colspan="3">Lagging0.8~Leading0.8</td>
</tr>
<tr>
<td>THDI</td>
<td style="text-align: center;" colspan="3">＜3%</td>
</tr>
<tr>
<td>AC connection</td>
<td style="text-align: center;" colspan="3">3W+PE</td>
</tr>
<tr>
<td>Topology</td>
<td style="text-align: center;" colspan="3">Transformerless</td>
</tr>
<tr>
<td style="text-align: center;"><strong><span style="color: #ff7e46;">Efficiency</span></strong></td>
<td colspan="3"></td>
</tr>
<tr>
<td>Max. efficiency</td>
<td style="text-align: center;">98.5%</td>
<td style="text-align: center;" colspan="2">98.6%</td>
</tr>
<tr>
<td>Euro efficiency</td>
<td style="text-align: center;" colspan="3">98.2%</td>
</tr>
</tbody>